Alternator A.R.K224DS

A.R.K224DS Alternator – High-Efficiency, Brushless Alternator for Industrial and Standby Applications

The A.R.K224DS alternator, engineered by Arken Power Solutions, is a three-phase brushless synchronous alternator designed for industrial, rental, telecom, and standby generator systems. Utilizing a self-excited AVR-regulated system (SX460 standard, SX440 optional), it offers ±1% voltage regulation, THD below 5%, and efficiency up to 88.6%. With Class H insulation, IP23 protection, and a dynamically balanced rotor, the A.R.K224DS ensures stable and reliable performance under all load conditions. It complies with IEC60034, BS5000, NEMA MG1-22, and ISO9001 standards, making it an ideal choice for demanding environments requiring consistent power output and durability.

Alternator Model

A.R.K224DS

50Hz (kVA)

45

60Hz (kVA)

56.3
Control SystemSELF EXCITED
A.V.R. OPTIONAL SX440
Voltage Regulation ± 1.0 %
Sustained Short Circuit>300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Voltage Range: 190–480 V (configurable in star, delta, or parallel star connection)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced load), <1.5% (no-load)

  • Sustained Short Circuit Current: >300% of rated current

  • Efficiency: Up to 88.6% depending on voltage and frequency

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Excitation System: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 optional, MX341 / MX321 (PMG) optional

  • Short Circuit Ratio (1/Xd): 6.0 typical

Reactances (Per Unit, Saturated)

  • Xd (Synchronous): 2.19–3.03

  • X’d (Transient): 0.16–0.22

  • X’’d (Subtransient): 0.10–0.15

  • Xq (Quadrature): 1.01–1.40

  • X’’q (Quadrature Subtransient): 0.13–0.16

  • X₂ (Negative Sequence): 0.12–0.14

  • X₀ (Zero Sequence): 0.08–0.10

  • Leakage Reactance (XL): 0.07–0.10

  • Time Constants:

    • Transient (T’d): 0.025 s

    • Subtransient (T’’d): 0.006 s

    • Armature (Ta): 0.005 s

    • Open Circuit Field (T’do): 0.65 s

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23 (optional IP44 with 5–10% derating)

  • Cooling: Self-ventilated air cooling

    • 50 Hz: 0.216 m³/s (458 cfm)

    • 60 Hz: 0.281 m³/s (595 cfm)

  • Frame: Steel structure with cast aluminum front and rear covers

  • Stator: Double-layer winding with auxiliary winding, 2/3 pitch eliminates triple harmonics

  • Rotor: Damped cage rotor, dynamically balanced per BS6861 standards

  • Bearings:

    • Drive End: 6315-2RS (ISO sealed-for-life)

    • Non-Drive End: 6310-2RS (ISO sealed-for-life)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (star, delta, or parallel star)

  • Stator Resistance: 0.181 Ω/phase (22°C, star connection)

  • Rotor Resistance: 0.59 Ω (22°C)

  • Rotor Inertia (WR²): 0.3667 kg·m² (double bearing) / 0.3987 kg·m² (single bearing)

Dimensions & Weight

  • Wound Rotor Weight: 70.58 kg (double bearing) / 78.95 kg (single bearing)

  • Wound Stator Weight: 75 kg

  • Complete Alternator Weight: 280 kg (double bearing) / 271 kg (single bearing)

  • Shipping Weight: 294–301 kg (crated)

  • Packing Dimensions: 97 × 57 × 96 cm

Regulation & Control

  • Excitation: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / MX341 / MX321 optional

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • RFI Suppression: BS EN 61000-6-2 & BS EN 61000-6-4, VDE 0875G/N compliant

  • Standards Compliance: IEC60034, GB755, BS5000, VDE0530, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 Quality Management System

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Cooling Air Requirement: 0.216–0.281 m³/s depending on frequency

  • Noise & Vibration: Balanced per BS6861 mechanical standards

Performance Summary

  • Efficiency Range: 86.6–88.6%

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% rated current

  • Applications: Prime power, standby, rental, telecom, mobile, lighting tower, refrigeration, and railway generator systems

Datasheet