Alternator A.R.K274J

A.R.K274J Alternator – Premium Efficiency Brushless Alternator for Industrial and Standby Applications

The A.R.K274J alternator, engineered by Arken Power Solutions, is a three-phase, brushless synchronous alternator designed for prime, rental, telecom, mobile, lighting tower, and standby generator systems. It features a self-excited AVR-controlled excitation system (SX460 standard, SX440 optional), ensuring voltage regulation within ±1%, THD below 5%, and efficiency up to 93%. Built with Class H insulation, IP23 protection, and sealed-for-life bearings, the A.R.K274J delivers long-lasting reliability and stable power in demanding industrial environments. Fully compliant with IEC60034, BS5000, VDE0530, NEMA MG1-22, and ISO9001, this alternator guarantees dependable performance and ease of integration in all professional generator systems.

Alternator Model

A.R.K274J

50Hz (kVA)

230

60Hz (kVA)

281
Control SystemSELF EXCITED
A.V.R. OPTIONAL SX440
Voltage Regulation ± 1.0 %
Sustained Short Circuit >300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Rated Voltage Range: 190–480 V (reconfigurable for series star, parallel star, or delta)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced load), <1.5% (no-load)

  • Sustained Short Circuit Current: >300% of rated current

  • Efficiency: Up to 93%

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Excitation System: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / AS440 optional, MX341 / MX321 (PMG optional)

  • Short Circuit Ratio (1/Xd): 6.0 typical

Reactances (Per Unit, Saturated)

  • Xd (Synchronous): 1.939–2.651

  • X’d (Transient): 0.103–0.164

  • X’’d (Subtransient): 0.070–0.096

  • Xq (Quadrature): 0.886–1.206

  • X’’q (Quadrature Subtransient): 0.123–0.163

  • X₂ (Negative Sequence): 0.098–0.117

  • X₀ (Zero Sequence): 0.037–0.048

  • Leakage Reactance (XL): 0.052–0.081

  • Time Constants:

    • Transient (T’d): 0.045 s

    • Subtransient (T’’d): 0.015 s

    • Open Circuit Field (T’do): 1.27 s

    • Armature (Ta): 0.03 s

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23 (optional IP44 with 5–10% derating)

  • Cooling: Self-ventilated air cooling

    • 50 Hz: 0.514 m³/s (1090 cfm)

    • 60 Hz: 0.617 m³/s (1308 cfm)

  • Frame: Heavy-duty steel structure with cast aluminum front and rear covers

  • Stator: Double-layer winding with auxiliary winding; 2/3 pitch design to eliminate triple harmonics

  • Rotor: Damped cage rotor, dynamically balanced per BS6861 standards

  • Bearings:

    • Drive End: 6315-2RS (ISO, sealed-for-life)

    • Non-Drive End: 6310-2RS (ISO, sealed-for-life)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (series star, parallel star, or delta)

  • Stator Resistance: 0.0126 Ω/phase (22°C, series star connection)

  • Rotor Resistance: 2.08 Ω (22°C)

  • Rotor Inertia (WR²): 2.3744 kg·m²

Dimensions & Weight

  • Wound Rotor Weight: 271.9 kg

  • Wound Stator Weight: 304 kg

  • Complete Alternator Weight: 727 kg

  • Shipping Weight: 740 kg (crated)

  • Packing Dimensions: 123 × 67 × 103 cm

Regulation & Control

  • Excitation: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / AS440 / MX341 / MX321 optional

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • RFI Suppression: BS EN 61000-6-2 & BS EN 61000-6-4, VDE 0875G/N compliant

  • Standards Compliance: IEC60034, GB755, BS5000, VDE0530, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 Quality Management System

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Cooling Air Requirement: 0.514–0.617 m³/s depending on frequency

  • Noise & Vibration: Balanced per BS6861 mechanical standards

Performance Summary

  • Efficiency Range: 92.4–93.0%

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% rated current

  • Applications: Prime power, standby, rental, telecom, mobile, lighting tower, refrigeration, and railway generator systems